Details
HTC11 Series Tower Online UPS 1-3kVA 2.0 (220V/230V/240V)
The HTC11 Series Tower Online UPS 1-3kVA 2.0 is the upgraded version of the original HT11 1-3kVA model. Designed to align with modern energy-saving and emission-reduction standards, this 2.0 version features a more compact design, enhanced performance, and improved cost-efficiency—delivering better value without compromising quality.
With a power range from 1kVA to 3kVA, it’s ideal for a wide variety of applications including:
-
Small data centers
-
Bank branches
-
Telecom service halls
-
Office environments
-
Edge computing scenarios
Key Features
-
Wide Input Voltage Range
Operates efficiently across a broad voltage range with input power factor > 0.99 -
High Output Performance
Delivers output power factor of 1.0 and upgraded overload capability -
Comprehensive Protection
Built-in safeguards against over-voltage and short-circuits -
Versatile Communication Interfaces
Equipped with RS232, RS485, AS400, dry contact, USB, and SNMP card support -
Advanced Display Options
LCD/LED display for real-time monitoring of system operation -
Smart Cooling System
Automatic fan speed adjustment for optimal thermal management -
Environmental Sensors
Includes external environment and battery temperature sensors -
Flexible Charging
1–12A adjustable charger for adaptable battery management -
Battery Compatibility
Fully supports Lithium battery configurations
Ready to power your critical systems with stability, efficiency, and intelligence—HTC11 Series 2.0 is your smart UPS solution for the next generation of infrastructure needs.
Specifications
HT1101CL | HT1101CS | HT1102CL | HT1102CS | HT1103CL | HT1103CS | |
System Capacity | 1kVA | 2kVA | 3kVA | |||
Phase | Single Phase in, Single Phase out | |||||
Battery Cold Start | Standard | |||||
Input Volatge Range | 110VAC~300VAC | |||||
176VAC~276VAC for 100% load; 276VAC~300VAC for 50% load; 110VAC~176VAC load decrease linearly from 100%~50% | ||||||
Transfer Voltage Range | 220/230/240VAC | |||||
-Line low transfer | 110VAC | |||||
-Line low recovery | 120VAC | |||||
-Line high transfer | 300VAC | |||||
-Line high recovery | 290VAC | |||||
Input Current | ||||||
Rated Current | 4.9A | 9.7A | 14.5A | |||
Input Power Factor | ≥0.99 | |||||
THDi | <3% (100% Linear load); <5% (non-linear load) | |||||
Input frequency Range | 50/60±5Hz(Default),±1Hz/±3Hz(Optional) | |||||
Output | ||||||
Frequency adaptable | Settable | |||||
Power | ||||||
Apparent Power(KVA) | 1 | 2 | 3 | |||
Active Power(KW) | 1(0.9 for 200VAC/208VAC) | 2(1.8 for 200VAC/208VAC) | 3(2.7 for 200VAC/208VAC) | |||
Output Voltage | ||||||
-Waveform(Bat. Mode) | Pure Sine Wave | |||||
Rated Voltage | 220/230/240VAC, 200/208VAC (PF=0.9) | |||||
-Voltage regulation | ± 1 % | |||||
- Dynamic response | ≤5% (0% - 100% -0%) | |||||
- Dynamic recovery | ≤40ms (0% - 100% -0%) | |||||
- Voltage distortion | ≤1% THD,linear load | |||||
≤ 5% THD, non-linear load | ||||||
Output Frequency | ||||||
Synchronization range | Mains mode: follow the mains frequency,Battery mode: 50/60Hz±0.1% | |||||
Transfer Time | ||||||
-Line mode to battery mode | 0 | |||||
-Inverter to bypass | 2ms | |||||
Effciency | ||||||
-Line mode with battery full charged | 94.5%@100% load | 95%@100% load | 95.5%@100% load | |||
-ECO mode | 98.0% | |||||
-Battery mode | 89.5%@100% load | 91.5%@100% load | 91.5%@100% load | |||
Noise(1m away) | <43dB@<60%load,<47dB@>60%load | <50dB@<60%load,<55dB@>60%load | ||||
Overload Capability(Inverter) | 102%~110%: Transfer to bypass after 30mins | |||||
110%~125%: Transfer to bypass after 10mins | ||||||
125%~150%: Transfer to bypass after 30s | ||||||
Overload Capability(Battery Mode) | 102%~110%:Transfer to bypass after 1min | |||||
110%~125%: Transfer to bypass after 10s | ||||||
125%~150%:shutdown after 5s | ||||||
Overload Capability (Bypass Mode) | <130%: Long time | |||||
130%~150%: shutdown after10mins | ||||||
150%~180%: shutdown after 5s | ||||||
Crest Factor | 3:1 | |||||
BATTERY | ||||||
Rating/Type | Depend on the capacity of external batteries | 12VDC/7Ah | Depend on the capacity of external batteries | 12VDC/7Ah | Depend on the capacity of external batteries | 12VDC/7Ah |
Quantity | 3 | 6 | 8 | |||
DC Voltage | 36VDC | 72VDC | 96VDC | |||
Back-up Time | Depend on the capacity of external batteries | 3mins @80% load | Depend on the capacity of external batteries | 3mins @80% load | Depend on the capacity of external batteries | 3mins @80% load |
Battery Charger | ||||||
-Charging Voltage | ||||||
-Charging Current | 1-12A(Settable) | 1A | 1-12A(Settable) | 1A | 1-12A(Settable) | 1A |
- Charging Time | Depend on the capacity of external batteries | 8h recharge to 90% | Depend on the capacity of external batteries | 8h recharge to 90% | Depend on the capacity of external batteries | 8h recharge to 90% |
INDICATOR & ALARM | ||||||
-Display | LED+LCD | |||||
-Discharge | Sound once every 2 minutes | |||||
-Low Battery Voltage | Sound once every 6s | |||||
-Battery Overload | Continuous beeping | |||||
-Input Voltage Abnormality(Include Sequential Negative,Ground wire not connected) | Sound once every 2 minutes | |||||
-Alarm | Sound once every 6s | |||||
-Fault | Continuous beeping | |||||
INTERFACE | ||||||
-RS232 | Support background software through standard cables | |||||
-Input | IEC C14 | IEC C20 | ||||
-Output | 2 National standard sockets | 4 National standard sockets | 3National standard sockets+1 20A connecting terminal | |||
OPTION | ||||||
-SNMP Card | Monitor the machine through the network | |||||
-AS400 Dry Contact | Pluggable DB9 dry connector card or phoenix terminal | |||||
-USB | B-type USB port | |||||
-RS485 | RS485 communication interface | |||||
-EPO | Emergency power off | |||||
External Battery Temperature | External battery temperature detection | |||||
-RJ45 Surge Protection | Port Surge Protection | |||||
-BMS | Dry contact for Lithium Battery BMS | |||||
MECHANICAL | ||||||
-W*D*H(mm) | 144*350*224 | 144*350*224 | 144*410*223 | 190*405*330 | 144*410*223 | 190*405*330 |
-W*D*H(mm)(Package size) | 238*446*311 | 238*446*311 | 244*506*308 | 280*520*410 | 244*506*308 | 280*520*410 |
-Net weight (KG) | 4.3 | 10.3 | 5.8 | 21.1 | 6.2 | 25.5 |
-Gross weight (KG) | 5.6 | 11.6 | 7.1 | 23 | 7.5 | 27.5 |
Color | Black |
View more about HTC11 Series Tower Online UPS 1-3kVA 2.0 (220V/230V/240V) on main site