HT33 Series Tower Online UPS 60-500kVA (380V/400V/415V)
The series Tower Online UPS is a high stability and scalability product for medium and large data center. The series has 60kVA, 80kVA, 90kVA, 100kVA, 120kVA, 150kVA, 200kVA, 250kVA, 300kVA, 400kVA, 500kVA can be chosen. And it supports swappable, each power module capacity reaches 500kVA in one cabinet but footprint less than 1.45m2.
Key Features
-
High Efficiency, up to 96%
-
High input PF>0.99; Input current THDi<3%
-
Muti-protection, as temperature, overload, battery under voltage, fan failures, short-circuit
-
Battery cold start
-
Battery management: smart charging control, auto maintenance, greatly extend the battery life
-
High power density
-
Parallel up to 1500kVA
-
Modular design of subsystem, convenient for field maintenance
-
Friendly Operation Interface, touch LCD Screen
Specifications
Model | HT33060X | HT33080X | HT33090X | HT33100X | HT33120X | HT33150X | HT33200X | HT33250X | HT33300X | HT33400X | HT33500X | ||
System Capacity | 60kVA | 80kVA | 90kVA | 100kVA | 120kVA | 150kVA | 200kVA | 250kVA | 300kVA | 400KVA | 500KVA | ||
Input | Dual Input | Standard | Optional | Standard | |||||||||
Phase | 3 Phase+Neutral+Ground, 380V/400V/415V(line-line) | ||||||||||||
Input Voltage Range | 304~478Vac (Line-Line),full load 228V~304Vac (Line-Line),load decrease linearly according to the min phase voltage |
||||||||||||
Rated Frequency | 50/60Hz | ||||||||||||
Input Frequency Range | 40Hz~70Hz | ||||||||||||
Input PF | >0.99 | ||||||||||||
Input THDi | <3% (100% Linear load) | ||||||||||||
Bypass | Rate Voltage | 380/400/415Vac (Line-Line) | |||||||||||
Rate Frequency | 50/60Hz | ||||||||||||
Input Voltage Range | Settable, -40%~+25% | ||||||||||||
Bypass Frequency Range | Settable, ±1Hz, ±3Hz, ±5Hz | ||||||||||||
Bypass Overload | 125% long term operation 130% for 10 mins 150% for 1 min >150% for 300ms |
110% long term operation 125 % for 5 mins 150% for 1 min >150% for 1s |
|||||||||||
Output | Rate Voltage | 380/400/415Vac (Line-Line) | |||||||||||
Voltage Regulation | 1% for balance load; 1.5% for unbalance load | ||||||||||||
Rate Frequency | 50/60Hz | ||||||||||||
Voltage Precision | 0.1% | ||||||||||||
Output PF | 1 | ||||||||||||
Output THDu | <1% , Linear load; <5.5%, Non-linear load | ||||||||||||
Crest Factor | 3:1 | ||||||||||||
Inverter Overload | 110% for 1 hour; 125% for 10 mins ;150% for 1 min; >150% for 200 ms | ||||||||||||
Battery | Voltage | ±240Vdc | |||||||||||
Battery Number | 40pcs (Settable: even number from 32 to 44) | ||||||||||||
Voltage Precision | ±1% | ||||||||||||
Charge Power | up to 20% * Output active power | ||||||||||||
Battery Cold Start | Optional | Standard | |||||||||||
System | Efficiency | AC Mode | 95% | 96% | 95% | 96% | 95% | 96% | |||||
ECO Mode | 99% | ||||||||||||
Battery Mode | 95% | 96% | 95% | 96% | 95% | 96% | |||||||
Display | 10.4"(240kVA-500kVA) or 7''(60kVA-200kVA) touch screen LCD + LED + keyboard | ||||||||||||
IP Class | IP 20 | ||||||||||||
Interface | RS232,RS485, Programmable Dry Contact, USB | ||||||||||||
Option | SNMP Card, Parallel kit, SPD, LBS, Dust filter | ||||||||||||
Temperature | Operation: -40~70 ℃ | ||||||||||||
Relative Humidity | 0~95% Non-condensing | ||||||||||||
Altitude | <1000m. Within 1000m to 2000m, 1% power derating for every 100m rise | ||||||||||||
Noise (1 meter) | 65dB @ 100% load, 62dB @ 45% load | ||||||||||||
Applicable Standards | Safety: IEC/EN 62040-1 EMC: IEC/EN 62040-2 Performance: IEC/EN 62040-3 | ||||||||||||
Physical | Weigh (kg) | 170 | 210 | 231 | 210 | 266 | 305 | 350 | 445 | 490 | 700 | 900 | |
Dimension W*D*H (mm) | 600*980 *950 |
600*980 *1150 |
600*980 *1400 |
600*980 *1150 |
600*980 *1400 |
650*960 *1600 |
650*960 *1600 |
650*970 *2000 |
650*970 *2000 |
1050*1000 *2 |