Details
HT33 Series Tower Online UPS 10-40kVA (380V/400V/415V)
The series Tower Online UPS for small load scenarios, and widely used in office, health care equipment and the mall. It has 10kVA, 15kVA, 20kVA, 30kVA, 40kVA can be chosen, and supports 8 units parallel. Otherwise, the 20kVA and 30kVA product can also be used in industrial site, such as ceramic factories, glass factories and other processing industries.
Key Features
-
High Efficiency,up to 96%
-
High input PF>0.99;Input current THDi<3%
-
Muti-protection, as temperature, overload, battery under voltage, fan failures, short-circuit
-
Four circuit breakers, providing full protection when fault happens battery cold start
-
Full DSP control
-
Battery management: smart charging control, auto maintenance, greatly extend the battery life
-
Parallel up to 8 units
-
Friendly operation interface, high-resolution LCD screen
Specifications
Mode | HT33010XL | HT33010XS | HT33015XL | HT33015XS | HT33020XL | HT33020XS | HT33030XL | HT33030XS | HT33040XL | HT33040XS |
Main Input | ||||||||||
Grid System | 3 Phases + Neutral + Ground | |||||||||
Rated Input Voltage | 380/400/415VAC (Line-Line) | |||||||||
Rated Frequency | 50/60Hz | |||||||||
Input Voltage Range | 304~478Vac (Line-Line),full load; 228V~304Vac (Line-Line),load decreases linearly according to the min phase voltage |
|||||||||
Input Frequency Range | 40Hz~70Hz | |||||||||
Input Power Factor | >0.99 |
|||||||||
Input Current THDi | <4% (full Linear Load) | <3% (full Linear Load) | ||||||||
Bypass Input | ||||||||||
Rated Bypass Voltage | 380/400/415VAC (Line-Line) | |||||||||
Rated Frequency | 50/60Hz | |||||||||
Bypass Voltage Range | Selectable, default -20%~+15%; Upper limit: +10%, +15%, +20%, +25%; Lower limit: -10%, -15%, -20%, -30%, -40% |
|||||||||
Bypass Frequency Range | Selectable, ±1Hz, ±3Hz, ±5Hz | |||||||||
Bypass Overload | 125% Long term operation; 125%~130% for 10min; 130%~150% for 1min; |
|||||||||
Output | ||||||||||
Rated Inverter Voltage | 380/400/415VAC (Line-Line) | |||||||||
Rated Frequency | 50/60Hz | |||||||||
Output Power Factor | 1 | 0.9 | ||||||||
Voltage precision | ±1.5%(0-100% linear load) | |||||||||
Transient Response | <5% for step load (20% - 80% -20%) | |||||||||
Transient recovery | < 30ms for step load (20% - 100% -20%) | |||||||||
Output Voltage THDu | <1% (linear load); <5.5% (non-linear load) according to IEC/EN62040-3 |
<1% linear load; <6 (non-linear load) according to IEC/EN62040-3 |
||||||||
Inverter Overload | <110%, 60min; 110%~125%,10min; 125%~150%,1min; |
|||||||||
Frequency Regulation | 50/60Hz±0.1% | |||||||||
Synchronized Range | Settable, ±0.5Hz ~ ±5Hz, default ±3Hz | |||||||||
Synchronized Slew Rate | Settable, 0.5Hz/S ~ 3Hz/s, default 0.5Hz/s | |||||||||
Battery And Charger | ||||||||||
Battery Rate Voltage | ±240VDC | |||||||||
Charger Voltage precision | 1% | |||||||||
Charger Power | max=20% System Power | |||||||||
Efficiency | ||||||||||
Normal Operation | 95%max | >95% | >96% | |||||||
Battery Operation | 94.5%max | >95% | >96% | |||||||
System | ||||||||||
Display | LED + LCD | |||||||||
Interface | Standard: RS232, RS485 Option: SNMP, Dry Contact, Parallel kit, Battery cold start |
|||||||||
Environmental | ||||||||||
Operation Temperature | 0 ~ 40 ℃ | |||||||||
Storage Temperature | -40 ~ 70 ℃ | |||||||||
Relative Humidity | 0 ~ 95% (Non condensing) | |||||||||
Noise (1 meter) | 58dB @ 100% load, 52dB @ 45% load | 65dB @ 100% load, 62dB @ 45% load | ||||||||
Physical data | ||||||||||
Dimension (W*D*H,mm) |
250*660*530 | 250*840*715 | 250*660*530 | 250*840*715 | 250*680*770 | 350*738*1335 | 250*680*770 | 350*738*1335 | 250*836*770 | 500*840*1400 |
Weigh(Kg) | 31 | 51.5 (without battery) |
31 | 51.5 (without battery) |
50 | 89 (without battery) |
52 | 89 (without battery) |
61 | 140 |
View more about HT33 Series Tower Online UPS 10-40kVA (380V/400V/415V) on main site