HR33 Series Rack Online UPS 30-40kVA (380V/400V/415V)
The HR33 Series Rack-mounted Online UPS adopts online double conversion design, based on DSP full digital control, to provide a stable and uninterrupted power supply for important loads, which can eliminate surges, instantaneous high voltage, instantaneous low voltage, and "Power pollution" such as wire noise and frequency offset, provide customers with high-efficiency and high-power-density power supply guarantees. the UPS can be plugged into the 19-inch standard server cabinet of the micro-module data center. The single cabinet has a capacity of 40kVA/40kW, and the system supports 4 parallel.
Key Features
-
40kVA/40kW in 4U.
-
19'' cabinet available.
-
Rack or tower installation.
-
Up to 4 units in parallel.
-
High efficiency up to 95.5%.
-
Rack-mounted 3-phase UPS.
-
Colorful Touch LCD.
-
Optional Power Distribution & Battery Pack.
Specifications
MODEL | HR33010CL | HR33015CL | HR33020CL | HR33025CL | HR33030CL | HR33040CL |
Power Rating | 10KVA/10KW | 15KVA/15KW | 20KVA/20KW | 25KVA/25KW | 30KVA/30KW | 40KVA/40KW |
Main | ||||||
Input | 3 P + N+ PE | |||||
Rate Voltage | 380/400/415VAC (line-ine) | |||||
Rate Frequency | 50/60Hz | |||||
Input Voltage Range | 304~478Vac (line-ine),full load | |||||
228V~304Vac (line-ine),full load; 228V~304Vac(line-ine),derate from 75% to 100% load | ||||||
Input Frequency Range | 40Hz~70Hz | |||||
Input PF | >0.99 | |||||
Input THDi | <4% (100% Linear Load) | <3% (100% Linear Load) | ||||
Bypass | ||||||
Rate Voltage | 380/400/415Vac (line-ine) | |||||
Rate Frequency | 50/60Hz | |||||
Input Voltage Range | Selectable, -40%~+25% | |||||
Bypass Frequency Range | Selectable, ±1Hz, ±3Hz, ±5Hz | |||||
Bypass Overload | 125%, Long time;130%,10mins;150%,1min;>150%,1s | |||||
Output | ||||||
Rate Voltage | 380/400/415Vac (line-ine) | |||||
Rate Frequency | 50/60Hz | |||||
Output PF | 1 | |||||
Output THDu | <1% from 0% to 100% linear load <5.5% full non-linear load according to IEC/EN62040-3 |
<1% from 0% to 100% linear load <5% full non-linear load according to IEC/EN62040-3 |
||||
Inverter Overload | 110% for 1 hour;125% for 10 min;150% for 1min;>150% for 200ms | |||||
Battery | ||||||
Battery number | ±240VDC | |||||
Charger Accuracy | 1% | |||||
Charger Capacity | up to 20% *Output power | |||||
Battery Cold Start | Yes | |||||
Efficiency | ||||||
AC Mode | 95.0%max | 95.5%max | 96.0%max | 96.0%max | ||
Battery Mode | 94.5%max | 95%max | 95.5%max | 95.5%max | ||
System | ||||||
Display | LED + LCD+Touch Screen | |||||
Interface | RS232(only 10-25K), USB(only 40K), RS485, Programmable dry contact | |||||
Option | SNMP,parallel kit | SNMP,parallel kit,LBS | ||||
Environmental | ||||||
Operation Temperature | 0 ~ 40 ℃ | |||||
Storage Temperature | -40 ~ 70 ℃ | |||||
Relative Humidity | 0 ~ 95% Non condencing | |||||
Noise (1 meter) | 65dB @ 100% load, 62dB @ 45% load | |||||
Phisical data | ||||||
Dimension W*D*H (mm) | 438*780*130 | 438*780*130 | 438*700*174 | 438*700*174 | ||
Weigh (kg) | 25 | 30 | 41 | 41 |